camera_calibration_and_stereo_vision
This is an old revision of the document!
Summary
- Marker tracking using a pair of cameras is a common task, however setting up and calibrating the cameras can be challenging
- In the SoRo Adhesives project, we designed a stereo-vision setup; this setup can be adapted to different projects
- The scripts used are based on the work of Temuge Batpurev which is hosted on GitHub
Key Points
- Camera calibration relies on acquiring images of a checkerboard using two cameras (see image below)
- This file can be used to generate checkerboards for calibration
- Checkerboard images are used to obtain the intrinsic matrices and distortion coefficients of each camera individually
- The camera calibration process also outputs a value related to the quality of the calibration (RMSE) which should be less than 0.30
- Note that both camera frames must have the same dimensions for stereo calibration